This study makes a sampling investigation of the current construction and indoor thermal environment in the old street in the ancient town Qinmuchuan. Based on the statistic analysis of the practical measured data about indoor humidity and wind speed in summer and also climate adaptation of buildings by using Weather Tool 2011, it puts forward adaptable passive strategies for construction designs. In the later rebuilding of traditional residential dwellings, walls made of raw soil should be used to adjust the weather conditions in southern Shaanxi. Then, it suggests promoting new techniques and measures. meanwhile, passive designs for construction should be fully used for the enhancement of indoor thermal comfort. Given suitable conditions, the technology of active architectural energy saving can be employed.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Downloads

Published

2022-10-23

How to Cite

Haining, T. (2022). Indoor Thermal Comfort of Traditionally Residential Dwellings in Southern Shaanxi of China. Journal of Mines, Metals and Fuels, 66(9), 664–668. Retrieved from https://www.informaticsjournals.com/index.php/jmmf/article/view/31780

 

References

Tsinghua university Building Energy Research Center, 2016 Annual Report on China Building Energy Efficiency. Energy Efficiency, China architecture & Building Press, Beijing (annual Report).

Ren KB, Tian BF, Qiao MC. (2014): “Analysis of stability and reinforcement measures of rammed earth wall”. China Homes, 12, 319-320.

Li J, Yang L, Liu JP.(2008): “Research on indoor thermal comfort in summer and cold winter zone”. Sichuan Building Science, 34(4), 200-205.

Liang R, Zhu YY, LiuJP, Zhang Q, Hui SHK, Wu XX. (2016): “Three typical urban and rural residential buildings in South of Jiangsu”. Journal of Xi’an University of Science and Technology, 5, 357-362.

Gao Y, Wang MZ, Liu JP. (2013): “Analysis of the western mountainous areas of rural traditional cold humid climate adaptability construction mode”. Architecture Technique, 10, 112-117.

Yan J, Wang J. (2012): “Analysis of architectural culture and morphological characteristics of ankang dwellings”. Sichuan Building Science, 38(1),255-258.

Yan J, Wang J. (2012): “Ziyang settlement and architecture research”. Sichuan Building Science, 38(3),300-303.

Yang Q. (2010): “Study on indoor thermal comfort in the cold zone”. Xi’an university of architecture and Technology.

Meng D. (2011): “Study on Optimization of energy saving design for residential buildings in Hanzhong”. Xi’an university of architecture and Technology.

Li B, Du C, Yao R, et al. (2018): “Indoor thermal environments in Chinese residential buildings responding to the diversity of climates”. Applied Thermal Engineering, 129, 693-708.

Balyani H H, Sohani A, Sayyaadi H, et al. (2015): “Acquiring the best cooling strategy based on thermal comfort and 3E analyses for small scale residential buildings at diverse climatic conditions”. International Journal of Refrigeration, 57, 112-137.

Guo S, Yan D, Peng C, et al. (2014): “Status investigation and test on heating of residential buildings in winter in Shanghai”. Heating Ventilating & Air Conditioning, 6, 11-15.

Dong X, Yan Z, Wang Z. (2014): “Heating Modes Investigation and Indoor Thermal Environment Test Research on City Residential in Hot Summer and Cold Winter Zone”. Building Science, 16(9), 768-777.

Shi H, Wang Z, Yan Z. (2015): “Indoor design temperature research for heating in hot summer and cold winter zone”. Sichuan Building Science, 4, 123-127,131.

Zhu L, Qian XQ, Qian KL. (2013): “Investigation and analysis of Winter Energy utilization of Residential Buildings in Hangzhou”. Applied mechanics & materials, 409-410,531-536.